ProFlow Water softener Manuale di Servizio

Navigare online o scaricare Manuale di Servizio per Dispenser per l’acqua ProFlow Water softener. ProFlow Water softener Technical data Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - WATER SOFTENER

© 2014 erie water treatment TM-EN-ProFlow-Rev2014.05 Technical Manual WATER SOFTENER

Pagina 2

ELECTRONIC CONTROL PANEL Page 10 Picture 13 symbol button function  SCROLL to advance to the next parameter  UP to increase the value of the

Pagina 3

ELECTRONIC CONTROL PANEL Page 11 MANUAL REGENERATION It is possible to manually initiate a regeneration. 1. Press the scroll  button repeated

Pagina 4 - Page 4

ELECTRONIC CONTROL PANEL Page 12 PROGRAMMING INSTRUCTIONS – PARAMETER SET LEVEL  Before entering the programming mode, make sure that the cont

Pagina 5 - ASSEMBLY

ELECTRONIC CONTROL PANEL Page 13 SIMPLEX ECO: 1. Press the scroll  button and hold it for 5 sec until the display shows: 2. Within 10 sec,

Pagina 6

ELECTRONIC CONTROL PANEL Page 14 DUPLEX ECO ALTERNATING:  The 2 Simplex systems, that make up a Duplex system, must be programmed individually

Pagina 7 - INSTALLATION

ELECTRONIC CONTROL PANEL Page 15 DUPLEX/TRIPLEX ECO PARALLEL:  The 2/3 Simplex systems, that make up a Duplex/Triplex system, must be progr

Pagina 8

ELECTRONIC CONTROL PANEL Page 16 DIAGNOSTICS LEVEL Besides of all programming parameters, a series of operating parameters can be consulted

Pagina 9 - Stdby 1000 L

MAINTENANCE Page 17 ROUTINE CHECKS Regularly the user should perform a basic check to verify if the water softener is functioning correctly, on

Pagina 10

HYDRAULIC FLOW DIAGRAMS Page 18 SERVICE BACKWASH BRINE DRAW / SLOW RINSE FAST RINSE / REFILL

Pagina 11

Page 19

Pagina 12 - PARAMETER SET LEVEL

TABLE OF CONTENT & INSTALLATION RECORD Page 2 Table of content & Installation record ...

Pagina 13

TROUBLESHOOTING Page 20 PROBLEM CAUSE SOLUTION Hard (untreated) water to service Open or defective bypass Close or replace bypass Simplex only

Pagina 14

TROUBLESHOOTING Page 21 PROBLEM CAUSE SOLUTION Control valve fails to refill brine tank Improper refill time setting Verify that refill time

Pagina 15

ELECTRICAL WIRING DIAGRAMS Page 22 SIMPLEX TEMPO  = position switches = power lead  = drive motor  = auxilliary contact (24V, max. 500

Pagina 16 - System Check

ELECTRICAL WIRING DIAGRAMS Page 23 DUPLEX ECO - ALTERNATING  = position switches = flow meter  = power lead  = drive motor  = service

Pagina 17 - MAINTENANCE

DEFAULT PARAMETER SETTINGS Page 24 (1) When the Hardness unit is changed, the Exchange capacity per liter resin needs to be adjusted accordingl

Pagina 18 - SERVICE BACKWASH

COMPOSITION OVERVIEW Page 25 Model Resin volume PN Control valve, incl. EuroT transformer, 1” male BSP connections InterConnect cable Service V

Pagina 19 - Page 19

EXPLODED VIEW - SIMPLEX TEMPO/ECO Page 26

Pagina 20 - TROUBLESHOOTING

EXPLODED VIEW - SIMPLEX TEMPO/ECO Page 27 (*) Recommended Spare Part Item PN Description Remark (*) 1 PT/1035/BA Pressure tank 10x35 2

Pagina 21

EXPLODED VIEW - DUPLEX ECO ALTERNATING Page 28

Pagina 22 - ELECTRICAL WIRING DIAGRAMS

EXPLODED VIEW - DUPLEX ECO ALTERNATING Page 29 (*) Recommended Spare Part Item PN Description Remark (*) 1 PT/1035/BA Pressure tank 10x

Pagina 23

WARNING & SAFETY INSTRUCTIONS Page 3  Before you begin the installation of the water softener, we advise you read and carefully follow the

Pagina 24 - DEFAULT PARAMETER SETTINGS

EXPLODED VIEW - DUPLEX ECO PARALLEL Page 30

Pagina 25 - COMPOSITION OVERVIEW

EXPLODED VIEW - DUPLEX ECO PARALLEL Page 31 (*) Recommended Spare Part Item PN Description Remark (*) 1 PT/1035/BA Pressure tank 10x35

Pagina 26 - Page 26

EXPLODED VIEW - TRIPLEX ECO PARALLEL Page 32

Pagina 27 - Page 27

EXPLODED VIEW - TRIPLEX ECO PARALLEL Page 33 (*) Recommended Spare Part Item PN Description Remark (*) 1 PT/1035/BA Pressure tank 10x35

Pagina 28 - Page 28

EXPLODED VIEW - TIMER HEAD - SIMPLEX Page 34

Pagina 29 - Page 29

EXPLODED VIEW - TIMER HEAD - SIMPLEX Page 35 (*) Recommended Spare Part Item PN Description Remark (*) 1 70971 Power lead with plug

Pagina 30 - Page 30

EXPLODED VIEW - TIMER HEAD - DUPLEX ALTERNATING Page 36

Pagina 31 - Page 31

EXPLODED VIEW - TIMER HEAD - DUPLEX ALTERNATING Page 37 (*) Recommended Spare Part Item PN Description Remark (*) 1 70971 Power lead w

Pagina 32 - Page 32

EXPLODED VIEW - TIMER HEAD - DUPLEX/TRIPLEX PARALLEL Page 38

Pagina 33 - Page 33

EXPLODED VIEW - TIMER HEAD - DUPLEX/TRIPLEX PARALLEL Page 39 (*) Recommended Spare Part Item PN Description Remark (*) 1 70971 Power le

Pagina 34 - Page 34

OPERATING CONDITIONS & REQUIREMENTS Page 4  OPERATING PRESSURE: min. 1,4 / max. 8,3 bar  this system is configured to perform optimally a

Pagina 35 - Page 35

EXPLODED VIEW - VALVE BODY Page 40

Pagina 36 - Page 36

EXPLODED VIEW - VALVE BODY Page 41 (*) Recommended Spare PartItem PN Description Remark (*) 1 21/83 Drain connection  2 568/271/J B

Pagina 37 - Page 37

TECHNICAL DATA Page 42 Technical specifications: (1) Supplied with 230/24V-50Hz transformer. Performances @ 3 bar operating pressure and bri

Pagina 38 - Page 38

TECHNICAL DATA Page 43 Model Triplex Parallel Resin 3 x 25 3 x 50 3 x 75 3 x 100 3 x 125 3 x 150 Brine tank volume (ltr) 3 x 125 3 x 1

Pagina 39 - Page 39

AQUION, INC. Lammerdries-Oost 30c B-2250 Olen Belgium  +32 (0) 14-28.51.71  +32 (0) 14-28.51.70 RPR/RPM Turnhout BWT/TVA/VAT B

Pagina 40 - EXPLODED VIEW - VALVE BODY

© 2013 Aquion, Inc. PP-ProFlow-Rev2014.01 r 1 2.a 2.b 3.a 3.b

Pagina 41

© 2013 Aquion, Inc. PP-ProFlow-Rev2014.01 r 4.a 4.b r 5.a 5.b

Pagina 42 - TECHNICAL DATA

© 2013 Aquion, Inc. PP-ProFlow-Rev2014.01 6 7.a 7.b r 8.a 8.b

Pagina 43

© 2013 Aquion, Inc. PP-ProFlow-Rev2014.01 r 9 10 r 11 r 12

Pagina 44 - AQUION, INC

© 2013 Aquion, Inc. PP-ProFlow-Rev2014.01 13 14.a 14.b 14.c

Pagina 45

ASSEMBLY Page 5 CONTENT CHECK  Actual parts that you have received, may differ from the pictures/illustrations in these Instructions!  For

Pagina 46

© 2013 Aquion, Inc. PP-ProFlow-Rev2014.01 15

Pagina 47

© 2013 Aquion, Inc. PP-ProFlow-Rev2014.01

Pagina 48

© 2013 Aquion, Inc. PP-ProFlow-Rev2014.01

Pagina 49

ASSEMBLY Page 6 BRINE TANK Picture 1 11. Move the brine tank to the correct installation location; position it on a flat and level surface. Ma

Pagina 50

INSTALLATION Page 7 INLET & OUTLET  Check the water pressure at the place of installation of the water softener; it should never exceed 8,

Pagina 51

INSTALLATION Page 8 DRAIN  We recommend the use of a stand pipe with air trap.  To prevent backflow from the sewerage system into the wate

Pagina 52

START-UP Page 9 PRESSURIZING 1. Put the bypass system in 'bypass' position. 2. Make sure the electronic controller(s) of the

Commenti su questo manuale

Nessun commento